SECTION 3: WIRING AND INSTALLATION
PAGE 3-4 C27750-001
This section covers the installation, wiring and cabling of the Moog DS2100 Servo-drive series. A pictorial diagram
of a single-axis system, with typical components included, is shown in Figure 3.1. Users are directed to read Section
2, Safety Instructions, before proceeding with wiring and installation.
3.1 System Components
The following components are required to build a Moog brushless motor digital control system (refer to Figure 3.1).
The user supplies all components besides the DS2100, EMC-Brackets, motor and other accessory cabling.
3.1.1 A.C. Mains Power Interface
The DS2100 should be connected to a three-phase AC supply. Operation with a single-phase supply is only allowed
with the G361-x003 and G361-x006 variants of the drive. For single-phase operation, the phase supply voltage must
be limited to 230V and the input power to the drive limited to 1.1kW.
WARNING
-
This equipment must be permanently and reliably connected to Earth and
all conductive parts in the IP54 rated enclosure in which the DS2100 Series Servo-drive
is installed must be reliably connected to Protective Earth. A Protective Earth connection
must come directly from an approved AC mains network. Stranded copper-wire is
recommended to carry the earth.
FAILURE TO PROVIDE AN ADEQUATE EARTH MAY CAUSE SERIOUS
PERSONAL INJURY AND EQUIPMENT MALFUNCTION.