Moog DS2100 Manuel d'utilisateur Page 140

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 450
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 139
DS2100 User's Manual
SECTION 4: GETTING STARTED
PAGE 4-14 C27750-001
4.12 Autophasing
Once the high power has been applied the user can then perform an Autophasing operation. For all commutation types
the parameter “comofs” contains the mechanical offset angle between the commutation feedback and the motor stator.
16-bit full scale corresponds to one full mechanical revolution.
In certain cases the motor has a resolver or encoder built in that has been adjusted in the factory, this angle can then be
obtained from the motor datasheet.
Otherwise it is possible to do an automatic adjustment of this value using “Commutation Parameters
Open the ‘Commutation Parameters’ panel in the Motor Setup menu item
Select ‘Torque Mode’
Select “Start” in the “Commutation parameters” panel
Ensure that hardware drive enable input has +24V applied and enable the drive using the enable button
( ) in
the toolbar.
When the function has completed, save the parameters to NVM using the Save All parameters command in the
Parameter Utilities “Full Parameters Load/Save
Save all Parameters
Save All”.
Figure 4.21 Commutation Parameters
Both the hardware Drive Enable and the Windrive Drive Enable must be enabled
in order to enable the drive.
Warning: Ensure that all listed safety precautions are observed when enabling
the drive. Ensure that motor is securely mounted on a suitable fixture. Sudden and
considerable movement of the motor, with a risk of injury will occur during high
speed reversals if the motor is not securely mounted.
Vue de la page 139
1 2 ... 135 136 137 138 139 140 141 142 143 144 145 ... 449 450

Commentaires sur ces manuels

Pas de commentaire